Focus topic. FXE. Resolution but make it greater

April 20, 2026

As industrial components continue to reduce in size, X-ray inspection is crucial for detecting microscopic defects across a range of applications, from materials science to electronics failure analysis to biological samples. At the same time, obtaining high-quality data as quickly as possible so users can spend more time analyzing their data and producing actionable insights is also critical. This calls for high-power X-ray output and a stable, high-resolution beam. The FXE-160 Nano CT can rapidly examine sub-micron defects across a wide range of lab applications by leveraging external cooling and higher resolution.

Improved resolution

By increasing the FXE-160 Nano CT module’s ultimate resolving power, it is now capable of 0.7 µm resolution when using the high-power target. Figure 1 displays a typical image of a standard mask sample with clearly resolved 0.7 µm structures. The vertical and horizontal structures are clearly simultaneously resolved with high contrast.

Note: achieving such high resolution also requires that the full imaging chain be optimized, for example, by choosing appropriate optical magnification and detector properties. This is the integrator’s responsibility.

The maximum power density of each focusing mode has also increased. This means there is no compromise in power associated with the improved resolution. Therefore, finer details can be resolved with the same imaging speed as previously.  

The high-power mode can reach a resolution of 2.8 µm at up to 15 W target power. The microfocus mode can reach a resolution of 1.8 µm at up to 10 W of target power. And finally, the highest resolution achievable with the high-power target in nanofocus mode is 0.7 µm with a target power of up to 1.6 W.

 

“The maximum power density of each focusing mode has also increased. This means there is no compromise in power associated with the improved resolution.”

Christopher Nicholson, Product Manager

 

Figure 1. The 0.7 µm structures are clearly resolved by the FXE 160 nano CT.

Reliable stability

Fully exploiting the higher resolution capabilities of the FXE 160 Nano CT is best achieved in combination with the external cooling option which provides excellent focal spot stability. A highly stable focal spot is critical for long-term imaging measurements, particularly at very high resolutions or when producing detailed reconstructed images with 3D tomography. Cooling also enables the tube to operate continuously for long periods without overheating.

To highlight the benefits of external cooling on imaging performance, we measured the X-ray focal spot position over time. The results were compared using the FXE 160 nano and FXE 160 nano CT modules in microfocus mode. The differences between cooled and uncooled tubes are immediately apparent in Fig. 3a. 

The circles’ diameters represent the spatial extent of focal spot drift at the corresponding time, indicated by the different colors.

A cooled tube produces a significant reduction in spot drift, with a total drift of only 2 µm over 1 hour following a 30-minute warm-up period. In comparison, for the uncooled tube, the drift value is 18 µm for the same period.

The value of this increased stability in the X-ray spot position is directly evident in the test images shown in Fig. 3b and 3c. With cooling included, smaller features can be resolved (purple arrow) due to reduced focal-spot motion. Even for larger feature sizes of 10 µm (red rectangle), the contrast is significantly increased.

The FXE-160 Nano CT now offers increased resolution of 0.7 µm, higher power density, and improved focal spot stability. 

Figure 2. Resolution and power available in different operating modes using the high-power target. The thicker colored lines show behavior in the range 120-160 kV, and the thinner colored lines at 60 kV.
a)
b) With cooling kit
c) Without cooling kit

Figure 3. Comparative cooling results

a) Drift measurements for FXE 160 nano (left) and a cooled FXE 160 nano CT module (right). 
b) Test images obtained with and 
c) without the cooling kit, highlighting a significant performance enhancement with cooling.

The benefits of the improved FXE-160 Nano CT are:

  • Achieve finer detail detection: 0.7 µm resolution with the high-power target (HPT) improves the accuracy of imaging tiny features.
  • Process samples quickly: increased power density across all operational modes enables fast, high-quality imaging.
  • Reduce errors and improve consistency: increased focal spot stability supports reliable imaging, especially over long periods or at high resolutions.

If you are working with sub-micron inspection or pushing imaging limits, we are ready to support you.
Let’s discuss your applications, system setup, and performance goals.
Get in touch to take the next step.

Latest three news

Focus topic. A conversation with Jan Bressendorff and Allen Gress about pipeline weld inspection

October 8, 2026

On a pipeline job, the X-ray system is chosen for the weld, not from a catalog. Pipe size and access determine how the crew can inspect it. The procedure sets what the image must show. Heat, weight and exposure time shape the working day. A poor choice can cost hours. A good one helps the crew get an image the inspector can assess without needless delay.

Read more

Focus topic. The HP/15 builds on two decades of proven HP/11 performance for digital detectors, in-line inspection and CT.

September 21, 2026

For two decades, the HP/11 has been the reference minifocus X-ray tube for high-resolution and high throughput radiography. The HP/15 keeps everything that made it trusted, and reengineers the rest for digital detectors, in-line inspection and computed tomography.

Read more

From the field. Cooler leakage with Pierre-Emmanuel Rigot at X-RIS

September 10, 2026

This is not primarily a story about a cooler leak - it is a story about what happens when insight arrives too late. About the cost of operating without remote access. About the difference between reacting to failures and preventing them. And about how weak signals only become meaningful over time when data is allowed to flow. At its core, this case shows why BLOX alone is not enough.

Read more